Your Cart Is Empty

Continue Shopping

  • Usa Flag 24 Years of Trust
  • |
  • Service Disabled Veteran Owned Small Business

Get Amazing Deals! Learn More

CyberPower Medical Grade M750L UPS - AC 120 V - 600 Watt - 750 VA - 3 x battery - lead acid - 7 Ah - USB, serial - output connectors: 6

Save

Item#:
M1100XL
MFG#:
M1100XL

Availability: Tangible Items - In Stock
ETA Date: 6/14/2023

You May Also Need

Lenovo T1.5kVA UPS - AC 200-240 V - 1.1 kW - 1100 VA - RS-232, USB - output connectors: 8 - for System x3500 M4

Lenovo T1.5kVA UPS - AC 200-240 V - 1.1 kW - 1100 VA - RS-232, USB - output connectors: 8 - for System x3500 M4

Price: $725.00

Lenovo RT1.5kVA UPS (rack-mountable / external) - AC 200-240 V - 1.35 kW - 1500 VA 7.2 Ah - Ethernet 10/100, RS-232, USB - output connectors: 8 - 2U - for System x3500 M4; ThinkAgile HX3721 Certified Node 7Y88

Lenovo RT1.5kVA UPS (rack-mountable / external) - AC 200-240 V - 1.35 kW - 1500 VA 7.2 Ah - Ethernet 10/100, RS-232, USB - output connectors: 8 - 2U - for System x3500 M4; ThinkAgile HX3721 Certified Node 7Y88

Price: $979.00

Lenovo RT2.2kVA UPS (rack-mountable / external) - AC 200-240 V - 1.98 kW - 2200 VA - Ethernet 10/100, RS-232, USB - output connectors: 9 - 2U - for System x3500 M4; ThinkAgile HX3721 Certified Node 7Y88

Lenovo RT2.2kVA UPS (rack-mountable / external) - AC 200-240 V - 1.98 kW - 2200 VA - Ethernet 10/100, RS-232, USB - output connectors: 9 - 2U - for System x3500 M4; ThinkAgile HX3721 Certified Node 7Y88

Price: $1,575.00

Lenovo RT3kVA UPS (rack-mountable / external) - AC 100-125 V - 2.7 kW - 3000 VA - Ethernet 10/100, RS-232, USB - output connectors: 7 - 2U - for System x3500 M4

Lenovo RT3kVA UPS (rack-mountable / external) - AC 100-125 V - 2.7 kW - 3000 VA - Ethernet 10/100, RS-232, USB - output connectors: 7 - 2U - for System x3500 M4

Price: $1,609.00

Description

The CyberPower M1100XL medical-grade UPS delivers clean, consistent backup power to sensitive medical equipment in hospitals and healthcare facilities. Designed for use in patient care vicinities, the M1100XL has been tested to meet all UL 60601-1 requirements, and includes hospital-grade plugs and outlets. The M1100XL also includes a built-in isolation transformer to minimize the current leakage and eliminate line noise, a tip-resistant mini-tower design, replaceable batteries, and a sealed, spray-resistant LCD panel.

Important Information

  • Battery backup
    Provides power to cover shorter-outages and supplies power long enough for equipment to properly shut down when utility power fails for longer periods of time. Helps prevent loss of data and minimizes the component stress caused by a hard shutdown.
  • Surge protection
    Diverts excess voltage away from sensitive electronic equipment during an AC power surge or power spike to prevent damage.
  • Line interactive topology
    Exists when a UPS has an autotransformer that regulates low voltages (e.g., brownouts) and over voltages (e.g., spikes) without having to switch to battery.
  • Automatic Voltage Regulation (AVR)
    Provides clean, consistent AC power by automatically regulating low voltages and over voltages, within defined tolerances, when incoming utility power has minor fluctuations.
  • Hospital-grade plugs & outlets
    Offer an added degree of safety and reliability to the input/output connections of hospital-grade equipment.
  • Sealed LCD screen
    Resists dirt, debris and spray, and can withstand repeated cleaning procedures common to patient-care environments.
  • Multifunction LCD panel
    Displays immediate, detailed information on the UPS battery and power conditions, alerting users to potential problems before they can affect critical equipment and cause downtime.
  • Ultra-quiet design
    Minimizes noise during operation for a quieter patient environment.

Specifications

Main Specifications
 
Product Description: CyberPower Medical Grade M1100XL - UPS - 880 Watt - 1100 VA - lead acid - 9 Ah
Device Type: UPS - external
Weight: 54.01 lbs
Input Voltage: AC 120 V
Output Voltage: AC 120 V ± 5%
Power Capacity: 880 Watt / 1100 VA
Input Connectors: Power NEMA 5-15P (hospital grade)
Output connectors: 6 x power NEMA 5-15R (hospital grade)
Battery: Lead acid - 9 Ah
Batteries Qty: 3
Networking: USB, serial
Dimensions (WxDxH): 8.7 in x 17 in x 6.7 in
Manufacturer Warranty: 3-year warranty
 
General
 
Device Type: UPS - external
 
Power Device
 
UPS Technology: Line interactive
Input Voltage: AC 120 V
Input Voltage Range: AC 90 - 150 V
Input Voltage Range (Adjustable): AC 88 - 150 V
Frequency Required: 60 Hz ± 3Hz
Input Connectors: Power NEMA 5-15P (hospital grade)
Power Output Connectors Details: 6 x power NEMA 5-15R (hospital grade)
Output Voltage: AC 120 V ± 5%
Power Capacity: 880 Watt / 1100 VA
Output Waveform: Sinewave
Surge Suppression: Yes
Surge Energy Rating: 1445 Joules
Circuit Protection: Circuit breaker
Power Factor (PF): 0.8
 
Battery
 
Quantity: 3
Technology: Lead acid
Voltage Provided: 12 V
Capacity: 9 Ah
Run Time (Up To): 36.6 min at 375 Watts
25 min at half load
13.4 min at 750 Watts
10 min at full load
Recharge Time: 8 hours
Transfer Time: 10 ms
Features: Sealed
 
Networking
 
Remote Management Interface: USB, serial
 
Expansion / Connectivity
 
Interfaces: 1 x USB - 4 pin USB Type B
 
Manufacturer Warranty
 
Service & Support: Limited warranty - 3 years
 
Environmental Parameters
 
Min Operating Temperature: 32 °F
Max Operating Temperature: 104 °F
Humidity Range Operating: 0 - 95% (non-condensing)
 
Dimensions & Weight
 
Width: 8.7 in
Depth: 17 in
Height: 6.7 in
Weight: 54.01 lbs